menu "Lua IR Module"

    config LUA_MODULE_IR_DEFAULT_CARRIER_HZ
        int "Default IR carrier frequency in Hz"
        default 38000
        range 30000 56000
        help
            Default carrier frequency used when transmitting IR signals.

    config LUA_MODULE_IR_DEFAULT_TX_RESOLUTION_HZ
        int "Default RMT TX resolution in Hz"
        default 1000000
        help
            Default RMT counter resolution for IR TX, 1MHz means 1 tick = 1us.

    config LUA_MODULE_IR_DEFAULT_RX_RESOLUTION_HZ
        int "Default RMT RX resolution in Hz"
        default 1000000
        help
            Default RMT counter resolution for IR RX, 1MHz means 1 tick = 1us.

    config LUA_MODULE_IR_RX_MAX_SYMBOLS
        int "Max symbols per IR RX frame"
        default 512
        range 32 2048
        help
            Maximum number of RMT symbols stored per learned IR frame.
            Raise this when learning long protocols (e.g. air-conditioner
            frames) or capturing repeated NEC bursts in a single shot.

endmenu